The Bigger Picture Starts With a Small Sample

A cleanroom can look spotless while contamination risks remain invisible to the eye. Proper cleaning, garbing, and controlled airflow all help protect the sterile compounding process. Environmental monitoring provides information about how those controls are performing.

For compounding pharmacies, an effective program connects sampling methods, suitable culture media, and consistent review of results. Understanding how these pieces work together helps teams make informed decisions about their cleanroom.

 

Air, Surfaces, and Personnel

Microorganisms can enter a compounding environment through people, materials, and everyday activities. Sampling different locations helps build a more useful picture of contamination control.

Air sampling evaluates recoverable airborne microorganisms. An active impaction air sampler draws a measured volume of air onto an agar surface. After incubation, recovered colonies can be counted and evaluated. Passive settle plates collect particles that fall onto exposed agar, but they cannot replace the impaction sampling required by USP <797>.

Surface sampling evaluates selected work surfaces and other locations identified in the facility’s sampling plan. Sampling locations and procedures should reflect the actual facility and be documented in its standard operating procedures. Sampled surfaces must be cleaned and disinfected afterward to remove media residue. USP <797> FAQs

Personnel sampling, including gloved fingertip and thumb sampling, supports evaluation of garbing and aseptic competency. It complements environmental sampling by providing information about the people working within the controlled environment. Media-fill testing evaluates aseptic technique through a simulated compounding process and serves a separate purpose. USP compounding standards overview

 

Choosing the Right Culture Media

The agar inside a plate matters just as much as the sampling location. Media selection should account for the organisms being recovered, the collection method, and the facility’s procedures. Residual disinfectants can also prove to be a variable when attempting to accurately measure cleanroom microbial activity as it can continue to inhibit organisms even after they reach the plate. So what media should you use? How can you prevent your left-over disinfectants from skewing your monitoring results?

 

Lecithin and Tween 80

It's true, residual disinfectants can affect the accuracy of your microbial monitoring, however, media containing suitable neutralizers additives, such as Lecithin and Tween 80, can help reduce that interference.

Neutralizer selection should account for the disinfectants used in the facility and the manufacturer’s stated capabilities for the formulation.

Hardy Diagnostics environmental monitoring guide

 

Tryptic Soy Agar (TSA)

Tryptic Soy Agar, commonly called TSA, is a general-purpose growth medium used to recover a broad range of microorganisms. Its soybean and casein digests provide nutrients that support many bacteria, along with yeasts and molds under suitable conditions.

This broad recovery makes TSA useful for routine environmental monitoring and tracking changes in microbial recovery over time. Prepared TSA is available in contact plates for sampling appropriate surfaces and in plate formats compatible with air-sampling equipment. The formulation, plate dimensions, and incubation conditions should match the facility’s monitoring method.

TSA with Lecithin and Tween 80 combines the broad growth support of TSA with ingredients that help neutralize certain disinfectant residues. During surface sampling, residual disinfectants can transfer onto the agar and continue suppressing microbial growth, potentially reducing the number of organisms recovered.

Hardy Diagnostics TSA instructions for use

 

Malt Extract Agar (MEA)

Malt Extract Agar, or MEA, is formulated to support the cultivation and recovery of yeasts and molds. Malt extract, dextrose, and peptones supply nutrients for fungal growth, while its mildly acidic conditions help discourage some bacterial growth.

For cleanroom monitoring programs that include a dedicated fungal medium, MEA provides an option for evaluating yeast and mold recovery. DiNovo offers prepared MEA plates and MEA contact plates containing Lecithin and Tween 80, allowing facilities to select a format suited to their sampling application.

Hardy Diagnostics MEA instructions for use

 

Sabouraud Dextrose Agar (SabDex)

Sabouraud Dextrose Agar, often called SabDex or SDA, is another medium used to cultivate and recover yeasts and molds. Its peptones provide nutrients, and dextrose supplies an energy source. The acidic formulation favors fungal growth while slightly inhibiting bacterial growth.

SabDex and MEA offer different nutrient formulations for fungal monitoring. Choosing between them should reflect the facility’s established monitoring method and recovery needs. The selected medium and incubation conditions work together to influence which organisms are recovered. Our prepared SabDex media options include SabDex only and SabDex with Lecithin and Tween 80. 

Hardy Diagnostics SabDex instructions for use

 

Matching the Plate to Your Program

When comparing media options for your cleanroom, take all the variables into consideration:

  • Sampling format: Contact plates for appropriate surfaces and plates compatible with the selected air sampler.
  • Formulation: Growth media and neutralizers suited to the target organisms and monitoring method.
  • Packaging: A configuration that fits the facility’s material-transfer procedures.
  • Handling requirements: Storage conditions, expiration dates, plate condition, and manufacturer instructions.

Hardy offers contact plates and prepared media for these applications. Its LokTight™ contact plates include a locking lid to help secure samples during transport. Selected formulations are also available irradiated and triple-bagged, providing options for facilities with staged cleanroom transfer procedures.

Browse Hardy Plates Here!

 

Putting Results to Work

Collecting samples is only part of the process. Results become useful when they are reviewed alongside sampling locations, operating conditions, cleaning records, and previous findings.

A recurring recovery at one location or a change following maintenance can help guide an investigation. Findings should be evaluated through the facility’s established procedures, with appropriate corrective actions and follow-up to assess their effectiveness.

FDA identifies inadequate environmental monitoring and failure to respond appropriately to changes in environmental quality as concerns in compounding facilities. A monitoring program needs a defined process for reviewing and acting on the information it produces. FDA guidance on insanitary conditions

Sampling frequencies and response requirements should follow the current USP <797> chapter and applicable regulatory requirements. Facilities preparing Category 3 compounded sterile preparations have additional environmental monitoring expectations. USP <797> FAQs

 

Supporting Your Monitoring Program

Thoughtful sampling, appropriate media, and consistent follow-through help pharmacies better understand their compounding environment.

DiNovo offers Hardy Diagnostics culture media and environmental monitoring supplies to support these workflows. Contact your DiNovo account manager for help exploring options that fit your facility’s sampling methods and cleanroom procedures!

Shop ALL environmental monitoring products at DiNovo.

 

Our culture media partner for November is Hardy Diagnostics! For a LIMITED TIME, save 5% on your next order of any Hardy products!

Use Code: BEYONDMONITORING

 

Delivering Compliance.

📞 866-963-6746
📧 customerservice@dinovomed.com
🔍 Check out all our environmental monitoring solutions HERE!